FAQ

I have been told that the max draw on the compressor should be around 29-30 amps and it does have a soft start on it to avoid the start up spike.
I have been told that the max draw on the compressor should be around 29-30 amps and it does have a soft start on it to avoid the start up spike.  Our A/C u...
Mon, 28 Mar, 2022 at 9:28 PM
How is the Integrel system different from a high power alternator?
The Integrel system is much more than a standard alternator; it is a complete power generation, storage, conversion and distribution system.   The Integre...
Mon, 28 Mar, 2022 at 9:30 PM
Why does the Integrel system need such a smart controller?
Integrel is a complete power generation, storage, conversion and distribution system, deeply embedded in the operation of the vessel. To achieve this withou...
Mon, 28 Mar, 2022 at 9:32 PM
Why is power sometimes quoted in kVA and sometimes in kW?
Power from an AC generator is quoted in kVA and power from a DC generator is normally quoted in kW. Integrel is a DC generator and so its power output is qu...
Fri, 30 Apr, 2021 at 3:29 PM
Does a catamaran need two systems, one on each engine?
A catamaran typically has an Integrel system fitted to each engine to provide redundant operation, however a dual installation is not mandatory on a cat.  ...
Mon, 28 Mar, 2022 at 9:36 PM
What are the main differences between a generator and an Integrel system?
The most obvious difference is that the Integrel system does not require a separate engine. This means that the fitting costs are less than for a stand-alon...
Mon, 28 Mar, 2022 at 9:37 PM
Can I remove a generator and replace it with an Integrel system?
An Integrel system will replace a generator of up to about 10kVA. The Integrel generator itself is fitted directly onto the propulsion engine; it occupies v...
Mon, 28 Mar, 2022 at 9:42 PM
What if I already have a large 12V battery bank?
What if I already have a large 12V battery bank, inverter, solar and it’s working pretty well. Can I replace my 180 amp alternator with this system? So I wo...
Mon, 28 Mar, 2022 at 9:43 PM
Are 48V solar regulators (MPPT) available?
Yes, there are high quality 48V solar regulators available. Using the solar array to charge the main battery banks directly is a good way to use the energy ...
Mon, 28 Mar, 2022 at 9:43 PM
Will I have problems running my main engine in generator only mode?
No. Integrel generates a lot of power at low engine revs. This optimises engine fuel consumption, which keeps the fuel bills down and ensures that the engin...
Fri, 30 Apr, 2021 at 3:37 PM